Dixell — Fault Codes
15 codes
Universal-XR / XR75CX / XR160D / XR170D
EE
— Data or memory (EEPROM) failure — the internal watchdog has detected a failure in data or in the internal memory of the controller.
XR06CX / XR60CX
CA
— Serious external alarm (digital input) — control may stop.
dA
— Door alarm — door open too long.
EA
— External alarm (digital input).
HA
— High temperature alarm (too warm).
LA
— Low temperature alarm (too cold).
LA2
— Condenser low temperature alarm.
P1
— Thermostat probe (Probe 1) fault or wrong probe type (NTC/PTC).
P2
— Evaporator probe (Probe 2) fault — defrost control affected.
P4
— Fourth probe failure.
XR160D / XR170D (i1F/i2F dijital giriş yapılandırması)
BAL
— Serious external alarm via the configurable digital input (i1F/i2F = bAL) — all relay outputs are switched OFF; on XR160D/XR170D the raw code is displayed as "BAL" (the equivalent alarm is collapsed to "CA" on other Dixell models).
EAL
— Generic (non-serious) external alarm via the configurable digital input (i1F/i2F = EAL) — on XR160D/XR170D the raw code is displayed literally as "EAL" (not abbreviated to "EA" as on XR60CX/XR06CX).
PAL
— Pressure switch alarm via the configurable digital input (i1F/i2F = PAL) — the compressor and regulation are stopped; on XR160D/XR170D the raw code is displayed as "PAL" (the equivalent alarm is collapsed to "CA" on other Dixell models).
XR60CX
HA2
— Condenser high-temp alarm (if Pb3 set as condenser).
P3
— Third probe (Probe 3) fault (e.g. condenser/product).