Fault Codes / Dixell / EE
DI
Dixell EE
Critical
Universal-XR / XR75CX / XR160D / XR170D — Data or memory (EEPROM) failure — the internal watchdog has detected a failure in data or in the internal memory of the controller.
Dixell EE: Data or memory (EEPROM) failure — the internal watchdog has detected a failure in data or in the internal memory of the controller. This fault typically halts operation and needs immediate attention.
Possible causes
- Electrical spikes/interference corrupted the non-volatile memory (no filters fitted, probe cables not separated from power cables).
- Internal controller fault (aging EEPROM chip or firmware corruption) requiring replacement.
Check steps
- Press any key to cancel the alarm (the 'rSt' message appears briefly), then check every parameter value against the expected setpoints and correct any wrong values.
- Fit mains filters (Dixell DIXL930/DIXL932 or equivalent) and re-route probe cables away from power cables; if the EE alarm recurs after correcting parameters, replace the controller.
Affected parts
- Dixell kontrolör (Universal-XR/XR75CX/XR160D/XR170D)
- EMI/RFI şebeke filtresi (DIXL930/DIXL932)
- Prob kablosu
Safety note
Disconnect all electrical connections before any maintenance. After recovery, re-verify all parameter values before leaving the unit running unattended.
Source: Dixell resmi servis kilavuzu (bagimsiz cift-dogrulandi) — Dixell Universal-XR Installing and Operating Instructions (Section 15 "ALARMS" table and 15.2 "'EE' ALARM" — verified directly in revision UXR12052013_REV1.3mm, same product family/section content as cited UXR10012015_REV1.4mm): "EE / Flashing / Data or memory failure / Alarm output ON; Other outputs unchanged."…