Samsung — Fault Codes
53 codes
—
E201
— Communication matching error (indoor units count mismatch).
E221
— Outdoor unit temperature sensor error.
E407
— Compressor down due to high pressure protection.
E461
— Compressor startup failure error.
E464
— IPM overcurrent protection (short circuit or lock).
E554
— Refrigerant gas leak detection.
DVM / Split
E101
— Indoor/outdoor communication error.
E102
— Communication error indoor ↔ outdoor (tracking).
E108
— Duplicate address (indoor/outdoor).
E121
— Room temperature sensor (Room-TH) fault.
E122
— Indoor heat exchanger inlet sensor (EVA-in) open/short.
E123
— Indoor heat exchanger outlet sensor (EVA-out) open/short.
E154
— Indoor fan error.
E163
— E163 = indoor unit EEPROM option-code error (not a generic EEPROM fault) — usually a misconfigured option code after a PCB swap or reinstall. Fix: reset option code via remote per service manual.
E202
— Communication error: outdoor not receiving from indoor.
E206
— Outdoor PBA communication (HUB/FAN/INV) error.
E206-C001
— Outdoor PBA communication: HUB PBA error.
E206-C002
— Outdoor PBA communication: FAN PBA error.
E206-C003
— Outdoor PBA communication: INV PBA error.
E206-C004
— Outdoor PBA communication: INV2 PBA error.
E231
— Outdoor condenser (COND) temperature sensor fault.
E251
— Discharge temperature sensor fault.
E320
— OLP (compressor overload) temperature sensor fault.
E416
— Discharge temperature too high (DIS-TH over).
E422
— Outdoor EEV (expansion valve) self-diagnosis error.
E440
— Heating operation prohibited (outdoor temp too high).
E441
— Cooling operation prohibited (outdoor temp too low).
E458
— Outdoor fan motor 1 error.
E462
— Total current / power-limit control (compressor stopped).
E465
— Compressor overload (V-limit/overcurrent).
E466
— DC link over-/under-voltage.
E468
— Current sensor error (inverter).
E469
— DC voltage sensor error.
E470
— Outdoor EEPROM read/write error.
E475
— Outdoor fan motor 2 error.
E484
— PFC overload.
E500
— IPM (IGBT) over-temperature.
DVM PLUS III
E215
— Indoor unit's address setting error on the MCU (there is same address among the MCUs).
E218
— Installed indoor unit count exceeds the MCU settings.
E307
— Oil balance temperature sensor malfunction.
E425
— Reverse phase or phase open (3-phase wiring of outdoor unit, R-S-T-N).
E440
— Heating operation prohibited because ambient temperature exceeds 30°C.
E453
— Overload error of outdoor unit's motor (by temperature).
E456
— Over current error of outdoor unit's motor.
E477
— Liquid refrigerant incoming protection error, associated with sump temperature sensor issue.
E563
— Model mismatching of indoor unit.
E603
— Communication packet error (baud rate error).
E608
— Can't detect ERV controller.
E618
— The connected indoor units to ERV exceeded 16 units.
E652
— Two wired remote controllers were set to the master mode.
E654
— Memory data error in the wired remote controller (MWR-WS00).
P701
— Floating switch error of indoor unit (1st detection).
P703
— EEV opening error of indoor unit (1st detection).