Bosch — Fault Codes
99 codes
Compress
1037
— Outside temperature sensor faulty — heating standby.
1038
— Invalid time/date value.
1041
— Voltage failure during screed drying.
1051
— No communication with external room temperature sensor.
1081
— Two master user interfaces in the system.
3081
— Configuration error: remote control.
3121
— Temperature limiter (heating circuit) triggered.
A01 (5201)
— Outdoor sensor T1 — open circuit (resistance too high).
A01 (5202)
— Outdoor sensor T1 — short circuit (resistance too low).
A01 (5204)
— Flow sensor T0 — open circuit.
A01 (5205)
— Flow sensor T0 — short circuit.
A01 (5207)
— Heat carrier outlet sensor TC1 fault.
A01 (5208)
— Heat carrier outlet sensor TC1 — short circuit.
A01 (5213)
— Inlet sensor TC0 fault.
A01 (5234)
— Pool temperature sensor TP1 fault.
A01 (5237)
— DHW sensor TW1 fault.
A01 (5240)
— Cooling outlet sensor TK1 fault.
A01 (5243)
— Cooling inlet sensor TK2 fault.
A01 (5246)
— Booster heater limiter (STB) or pressure switch tripped.
A01 (5265)
— Z1 PCB disconnected (CAN bus).
A01 (5269)
— 5269 is NOT a 'flow too low' alarm — it is the electric booster heater (EE) high-temperature cutout on sensor TC1 (>87°C, resets <80°C). Low-flow alarms belong under code 5252.
A01 (5271)
— Flow sensor T0 defective (plausibility).
A01 (5273)
— Z1 phase monitor tripped: one or more supply-voltage phases are missing (compressor control/supply). Check that all phases are present and carry voltage.
A01 (5294)
— Condensation guard tripped.
A01 (5298)
— High pressure alarm (compressor envelope exceeded).
A01 (5302)
— Compressor control system temperature over 110 °C.
A01 (5310)
— Hot gas (discharge) temperature too high.
A01 (5314)
— Discharge temperature sensor TR6 — open circuit.
A01 (5350)
— Compressor control failure – not running / locked rotor.
A01 (5362)
— Z1 overvoltage.
A01 (5366)
— Superheat of discharge gas too low (< 20 K).
A01 (5414)
— Condensate sensor TR3 — open circuit.
A01 (5420)
— Temperature sensor TR4 — open circuit.
A01 (5426)
— Temperature sensor TR5 — open circuit.
A01 (5432)
— Pressure sensor disconnected/faulty.
A01 (5452)
— Internal fault in inverter.
A01 (5507)
— Z1 MR1 high pressure warning.
A01 (5512)
— Compressor outside allowed envelope (>60 s).
A01 (5523)
— Short circuit in inverter (compressor control).
A01 (5533)
— Compressor sensor TR1 — open/short circuit.
A01 (5547)
— Heat source TB0 too low (brine/outdoor).
A01 (5571)
— Brine sensor TB0 — short circuit.
A01 (5573)
— Brine sensor TB0 — open circuit.
A01 (5577)
— Brine sensor TB1 — short circuit.
A01 (5579)
— Brine sensor TB1 — open circuit.
A01 (5593)
— EMS cable not connected or broken.
A01 (5594)
— Z1 air in the system.
A01 (5902)
— Compressor motor overload (overcurrent).
A01 (5903)
— Fault in compressor motor control.
A01 (5905)
— Supply voltage below 180 VAC (undervoltage).
A01 (5908)
— Initialization error of inverter control.
A01 (5917)
— Communication with heating pump PC0 disturbed.
A01 (5922)
— Supply voltage to pump PC0 too high.
A01 (5923)
— Heat carrier pump PC0 reports dry run.
A01 (5940)
— Air in heating pump PC0.
A01 (5981)
— Wrong rotation direction in compressor.
A01 (5984)
— No refrigerant in pump (compressor).
A01 (5987)
— Locked rotor (high motor load).
A01 (5989)
— Phase lost to compressor winding.
A01 (5993)
— Disturbances in Modbus communication.
A01 (5994)
— Low pressure in brine circuit (ground source).
A11
— No EMS BUS communication / internal connection interrupted.
A11 (1010)
— No communication via EMS BUS.
A11 (3061)
— No communication with heating circuit (mixing module).
A11 (3071)
— No communication with remote/room sensor.
A11 (3091)
— Room temperature sensor faulty.
A11 (3111)
— Configuration error: a room sensor/remote was replaced with a different type (with/without humidity sensor, e.g. CR10 ↔ CR10H) after one had already been learned. Fix: re-run the configuration wizard in the service (commissioning) menu.
A21 (1001)
— No communication system controller ↔ remote control.
A21 (3141)
— Humidity sensor faulty (room sensor).
A71 (3171)
— Low battery voltage in radio room sensor.
A91 (3181)
— No signal from radio room sensor.
H01 (5252)
— Flow at indoor unit restricted.
H01 (5285)
— Risk of frost in heating system.
H01 (5303)
— Z1 temperature too high (compressor protection).
H01 (5311)
— Hot gas temperature too high (TR6 > 110–120 °C).
H01 (5316)
— Discharge temperature sensor TR6 fault (repeated).
H01 (5331)
— Inverter system communication fault.
H01 (5448)
— Expansion valve VR0 — deviation (opened 20% more).
H01 (5508)
— High pressure guard MR1 tripped.
H01 (5513)
— Z1 dew point too high.
H01 (5524)
— Internal error in inverter — replace inverter.
H01 (5527)
— Heat pump overfilled (refrigerant).
H01 (5918)
— Flow < 50 l/h (air in system).
Compress / Logamatic EMS plus
1001
— No communication between system controller and remote control (room sensor shows A21/A22/A23/A24 depending on heating circuit).
1010
— No communication via EMS BUS connection — the local device hasn't received its EMS token from the bus master for 2 minutes.
1052
— No communication with external room temperature sensor module (heating circuit 2) — the installer still has this module selected although it isn't fitted.
1082
— Two master programming units in the system — the room sensor for heating circuit 2 has been incorrectly configured as a controller.
3061
— No communication with mixer module (heating circuit 1) — a mixing module was previously installed and now the installer module is unable to communicate with the room sensor over the EMS bus.
3071
— No communication with remote control (heating circuit 1) — a room sensor was previously installed and now the installer module is unable to communicate with the room sensor over the EMS bus.
A11 (1037)
— Internal program sequence error in control unit.
A21 (806)
— Room temp sensor heating circuit 1 fault — replace remote.
A21 (816)
— No communication with control unit heating circuit 1.
A41 (1010)
— No BUS communication (DHW/storage module).
A41 (1030)
— Internal data error in control unit — replace.
A41 (4051)
— Thermal disinfection failed.
A51 (812)
— Setting error solar module — check parameters.
A51 (813)
— Collector temp sensor — connection line to solar module faulty.
A61 (1010)
— No EMS plus BUS communication — heating circuit 1 module.
A71 (1010)
— No communication mixer/connection module.