ENTHALIO

Fault Codes / Bosch / A01 (5350)

BO

Bosch A01 (5350)

Critical

Compress — Compressor control failure – not running / locked rotor.

Bosch A01 (5350): Compressor control failure – not running / locked rotor. This fault typically halts operation and needs immediate attention.

Possible causes

Check steps

Affected parts

Safety note

High voltage – do not open DC link.

Source: Bosch resmi servis kılavuzu — Alarm List 8754, code 5350, Display Code A01, Installer: "Info Z1 Control failure on compressor — Compressor does not run, locked rotor." Matches app's 'Kompressor läuft nicht / blockierter Rotor.'

Reviewed by Anıl Güzeldemir — in the refrigeration machine room since 2006, developer of Enthalio.

Look up in Enthalio →

Related fault codes

No EMS BUS communication / internal connectionA11 Booster heater limiter (STB) or pressure switcA01 (5246) Hot gas temperature too high (TR6 > 110–120H01 (5311) Z1 phase monitor tripped: one or more supply-vA01 (5273) High pressure guard MR1 tripped.H01 (5508) No communication via EMS BUS.A11 (1010)