Stiebel Eltron — Fault Codes
45 codes
WPL / WPMsystem
10002
— Compressor or starting contactor stuck.
10003
— Minimum low-pressure monitor tripped.
10004
— High pressure limiter responded.
10005
— Low pressure switch triggered.
10006
— Minimum mid-pressure monitor tripped.
10013
— Min. low-pressure monitor < 0.9 bar abs tripped.
10015
— Frost protection monitor triggered in defrost mode.
10023
— HP sensor exceeded the limit.
10024
— Hot gas temperature exceeded the limit.
10025
— High-pressure sensor value out of permissible range.
10027
— HP does not rise above LP after compressor start.
10028
— Superheat at evaporator outlet/compressor inlet too long below limit.
10029
— High deviation of EXV opening from the characteristic curve.
10034
— Flow rate monitoring (heat output/flow/return).
10042
— Condenser outlet sensor value out of range.
10047
— Low-pressure monitor tripped during defrost.
10048
— Low-pressure monitor tripped during cooling.
10049
— Anti-freeze pressure sensor activated.
10099
— Oil sump temperature sensor value out of range.
10108
— Low supply voltage at FES.
10115
— Communication with FES not working correctly.
10227
— Maximum number of CRC error detections reached (WPM).
10228
— Error communicating with real-time clock (RTC).
10495
— Insufficient flow rate to start cooling operation.
10503
— Safety assembly triggered a gas warning.
10511
— Fan failure detected (no RPM) — ventilation module.
20012
— Outlet monitor for HP compressor tripped.
20014
— Outlet monitor for LP compressor tripped.
20022
— Start-error monitor for HP compressor tripped.
20033
— Minimum flow temperature undercut (setpoint 6.5 °C).
20037
— "Rotor stuck" monitor for LP compressor tripped.
20041
— "Rotor stuck" monitor for HP compressor tripped.
20045
— Compressor speed deviation (setpoint/actual) — LP compressor.
20050
— Min. flow temperature monitor (heat source).
20051
— Min. return temperature monitor (heat source).
20057
— Inverter main fault: IGBT overcurrent.
20058
— Inverter main fault: PFC IGBT overcurrent.
20064
— Inverter main fault: desaturation.
20065
— Inverter main fault: inverter IGBTs overtemperature.
20067
— Inverter main fault: rotor not turning as expected.
20073
— Inverter main fault: motor overspeed.
20077
— Inverter minor fault: compressor scroll overtemperature.
20100
— Low pressure below the SOA-LP limit.
20104
— High pressure above the SOA-HP limit.
30054
— Compressor thermistor protection relay triggered.