Fault Codes / Viessmann
VI
Viessmann — Fault Codes
51 codes
Vitocal
- 01 — System error — control processor faulty.
- 02 — Data error in basic settings.
- 03 — Configuration error (limited/no operation).
- 05 — Refrigerant circuit fault (EEV controller).
- 07 — Refrigerant circuit — message from the refrigerant circuit controller, heat pump stage 1.
- 09 — PV energy meter — self-consumption via the photovoltaic system not possible.
- 0A — Outdoor unit fault (shuts off).
- 0B — Outdoor unit warning — outside operating limits.
- 10 — Outside temperature sensor — short circuit.
- 18 — Outside temperature sensor — open circuit.
- 20 — Secondary flow temp sensor — short circuit.
- 21 — Secondary return temp sensor — short circuit.
- 24 — Short circuit, reversible suction gas temperature sensor — in heating mode the heat pump keeps running, in cooling mode the compressor switches off.
- 25 — Short circuit, liquid gas temperature sensor — compressor switches off.
- 28 — Secondary flow temp sensor — open circuit.
- 29 — Secondary return temp sensor — open circuit.
- 2C — Open circuit, reversible suction gas temperature sensor — in heating mode the heat pump keeps running, in cooling mode the compressor switches off.
- 2D — Open circuit, liquid gas temperature sensor — compressor switches off.
- 30 — Primary flow temp sensor fault.
- 31 — Primary return temp sensor fault.
- 32 — Evaporator temperature sensor fault.
- 38 — Open circuit, primary circuit flow temperature sensor (heat pump air or brine inlet) — emergency operation using return value +3K.
- 39 — Open circuit, primary circuit return temperature sensor (heat pump air or brine outlet) — emergency operation using flow value −2K.
- 3A — Open circuit, evaporator air-inlet temperature sensor — no room heating/cooling, only defrosting possible.
- 50 — DHW tank sensor (top) fault.
- 52 — DHW tank sensor (bottom) fault.
- 60 — Buffer tank temp sensor fault.
- 70 — Room temp sensor circuit 1 fault.
- A4 — Check valve — impermissible flow/temp rise.
- A6 — Secondary pump fault.
- A8 — Heating circuit pump 1 fault.
- A9 — Compressor switched off, heating via alternative source.
- AA — Defrost aborted.
- AC — Compressor shutdown (protection).
- AF — DHW charging pump fault.
- B0 — Device ID – HP won't start or runs at reduced efficiency.
- B1 — KM-BUS communication refrigerant controller 1.
- B5 — EEPROM fault (internal memory).
- B7 — KM-BUS communication outdoor unit.
- BF — Communication module wrong/faulty.
- C2 — Power supply of KM-BUS components.
- C5 — Utility lockout – compressor off (by energy supplier).
- C9 — Safety high-pressure switch tripped, compressor off.
- CA — Primary-circuit protection – compressor off.
- CB — Minimum primary flow temp (brine inlet) undershot.
- CC — Coding plug cannot be read, HP does not start.
- D1 — Compressor — safety chain tripped.
- D3 — Low-pressure fault, compressor switches off.
- D4 — Control high-pressure fault, compressor off.
- D6 — Flow switch detects no flow, compressor off.
- E0 — E0 LON participant: 'no communication via LON with the participant' — loss of communication with a SPECIFIC LON device (identified by system/participant number), not a blanket 'no LON communication at all'.