NIBE — Fault Codes
30 codes
F-Serie
1
— Sensor fault BT1 (outdoor temperature).
10
— Sensor fault BT10 (brine inlet). GP2 pump on manual.
16
— Sensor fault BT16 (evaporator). Auto reset.
2
— Alarm '2' (sensor fault BT2) is the heating medium SUPPLY (flow/Vorlauf) sensor, not the return (that is BT3). Additional heating is blocked; system falls back to condenser-out sensor (BT11).
220
— High pressure alarm from outdoor unit.
229
— Short compressor runs – stopped 3× shortly after start.
248
— Comm fault – no connection display↔base card.
3
— Sensor fault BT3 (heating return). Compressor blocked during DHW.
40
— Compressor phase 1 missing or below 160V.
41
— Compressor phase 2 missing.
42
— Compressor phase 3 missing.
43
— Faulty phase sequence.
44
— Overheated softstart — fuses for the soft start card are defective.
45
— Phase fault — motor protection on single phase (Norway) has probably been triggered.
50
— High pressure alarm – HP switch tripped repeatedly.
54
— Motor protection alarm — motor protection breaker tripped.
55
— Hot gas alarm – discharge temp over limit.
56
— Incorrect serial number — serial number does not exist.
57
— Incorrect firmware — serial number and firmware do not match.
58
— Pressure switch — high or low pressure switch has triggered.
6
— Sensor fault BT6 (hot water control). Auto reset.
60
— Low HTF (heat transfer fluid/brine) out — the temperature of the outgoing brine goes below the set minimum temperature.
63
— Low air flow — too low air flow at air flow sensor BS1.
64
— Low exhaust air temperature — exhaust air temperature has been below 16°C and not risen above 17°C within 60 minutes.
65
— High condensation water level — external level monitor.
66
— High condensation water level — alarm from level monitor in the condensation water container.
67
— Antifreeze protection supply air — supply air temperature (BT22) is below 5°C.
69
— Non-calibrated air flow sensor — the air flow sensor has not been calibrated.
70
— Permanent communication error input card — no communication with the input card.
71
— Permanent communication error base card.