Fujitsu — Fault Codes
58 codes
—
11
— Communication error between indoor unit and remote controller.
41
— Room temperature sensor error.
42
— Indoor unit heat exchanger sensor error.
51
— Indoor unit fan motor error.
94
— Trip detection (overcurrent or inverter fault).
97
— Outdoor unit fan motor error.
A1
— Discharge temperature 1 abnormal.
Airstage V-II
13.1
— Initial setting error (main PCB) (Error code 13.1).
14.1
— Communication error between outdoor units (Error code 14.1).
14.2
— Outdoor unit network communication 1 error (Error code 14.2).
14.5
— Outdoor unit network communication 2 error (Error code 14.5).
28.1
— Indoor unit number shortage (Error code 28.1).
28.4
— Auto address setting error (Error code 28.4).
5U.1
— Signal amplifier auto address setting error (Error code 5U.1).
61.5
— Outdoor unit reverse phase / missing phase wire error (Error code 61.5).
62.3
— Outdoor unit EEPROM access error (Error code 62.3).
62.6
— Inverter communication error (Error code 62.6).
62.8
— Outdoor unit EEPROM data error (Error code 62.8).
63.1
— Inverter error (Error code 63.1).
67.2
— Inverter PCB momentary power failure detection (Error code 67.2).
68.1
— Magnetic relay error (Error code 68.1).
68.2
— Rush current limiting resistor temp rise protection (Error code 68.2).
69.1
— Outdoor unit communication PCB parallel communication error (Error code 69.1).
71.1
— Discharge temp sensor 1 error (Error code 71.1).
71.2
— Discharge temp sensor 2 error (Error code 71.2).
72.1
— Compressor temp sensor 1 error (Error code 72.1).
72.2
— Compressor temp sensor 2 error (Error code 72.2).
73.3
— Outdoor unit heat exchanger liquid temp sensor error (Error code 73.3).
74.1
— Outdoor temp sensor error (Error code 74.1).
75.1
— Suction gas temp sensor error (Error code 75.1).
77.1
— Heat sink temp sensor error (Error code 77.1).
82.1
— Sub-cool heat ex. gas inlet temp sensor error (Error code 82.1).
82.2
— Sub-cool heat ex. gas outlet temp sensor error (Error code 82.2).
83.1
— Liquid pipe temp sensor 1 error (Error code 83.1).
83.2
— Liquid pipe temp sensor 2 error (Error code 83.2).
84.1
— Current sensor 1 error (Error code 84.1).
86.1
— Discharge pressure sensor error (Error code 86.1).
86.3
— Suction pressure sensor error (Error code 86.3).
86.4
— High pressure switch 1 error (Error code 86.4).
86.5
— High pressure switch 2 error (Error code 86.5).
92.1
— Compressor 2 error (Error code 92.1).
92.2
— Compressor 2 current value error (Error code 92.2).
93.1
— Inverter compressor start-up error (Error code 93.1).
94.1
— Trip detection (Error code 94.1).
95.5
— Compressor motor loss of synchronization (Error code 95.5).
97.1
— Outdoor unit fan motor lock error (Error code 97.1). [Code label corrected 2026-07-06 from 'E1:17' to the official value.]
97.4
— Outdoor unit fan motor undervoltage (Error code 97.4).
97.5
— Outdoor unit fan motor temperature abnormal (Error code 97.5).
9U.2
— Slave unit error (Error code 9U.2).
A1.1
— Discharge temperature 1 abnormal (Error code A1.1).
A2.1
— Discharge temperature 2 abnormal (Error code A2.1).
A3.1
— Compressor 1 temperature abnormal (Error code A3.1) — sensor/protection fault, NOT refrigerant undercharge. [Code label corrected 2026-07-06 from 'E1:24' to the official value.]
A3.2
— Compressor 2 temperature abnormal (Error code A3.2).
A4.1
— High pressure abnormal (Error code A4.1).
A4.2
— High pressure protection 1 (Error code A4.2).
A4.3
— High pressure protection 2 (Error code A4.3).
A5.1
— Low pressure abnormal (Error code A5.1).
AC.4
— Heat sink temperature abnormal (Error code AC.4).